APPLICATION NOTES

Copies of the Application Notes are available in both paper and electronic versions. Please go to the Sign-in/Information Request page to request a copy of any of our Application Notes. Please refer to the Application Note Number when requesting information.

Please also see our Product Note page for product related information.

NOTE NO. APPLICATION DESCRIPTION

RA_1201

Material Science

Cross Beam Ionizer Design for Plasma Monitoring”  Operating Principle and design of a Cross Beam Deflector Ionizer and its application as an Energy Filter and Noise Reducer  when used to sample plasmas

RA_1203

Material Science, Ion Chemistry

Characterization of a Novel Molecular Beam Mass Spectrometer Design: Energy Analysis of Pre-formed Ions”  Design and performance of a Molecular Beam System for highly accurate sampling of plasmas and energy anlysis of pre-formed ions.

RA_1402

Material Science

Axial Energy Analyzer: Energy Resolution”  Design and Operating principles of Axial Energy Filter with emphasis on Energy Resolution

RA_1403

Material Science

Axial Energy Analyzer:  Ion Kinetic Energy and SIMS Spectrum from a CuBe Alloy”  Sampling Ions with a wide energy distribution using the Axial Energy Anayzer during a SIMS Experiment

RA_1405

Material Science

Improvements in Signal-to-Noise and Minimization of analyzer related background contributions in ultra high vacuum residual gas analysis  Part I. Improvements in Signal-to-noise “  Shows how to lower background noise in UHV systems with a Tandem Ionizer/Energy Analyzer.

RA_1602

Material Science

A Filament Study:  Optimizing Filament Configurations for Measuring Appearance Potentials “  Shows various filament configurations and materials and the effect these have on the study of Appearance Poetenials.

RA_2001

General Quadrupole Theory

Resolution and Transmission of Quadrupoles: RF-DC and RF-only Operation”  Shows the effect of quadrupole rod size and RF frequency  on  Transmission, Resolution, Abundance Sensitivity and Mass Range

RA_2002

High Mass

High Resolution High Sensitivity RF-only Quadrupole Mass Spectrometry for Clusters Characterization and Deposition”  Cluster Analysis and Deposition using RF-only Quadrupoles

RA_2003

Material Science, Ion Chemistry

Optimizing Quadrupole Performance When Coupled with High Voltage Ion Sources”  Discusses how to improve Sensitivity and Peak Shape when looking at high energy ions from a source such as a plasma.

RA-2004

General Quadrupole Theory

Quadrupole Performance: Do Quadrupoles Discriminate Against High Masses “ Shows the effects of Quadrupole rod size, RF operating Frequency and Quadrupole pre- and post-filters on quadrupole transmission of high masses.

RA-2005

General Quadrupole Theory

Transmission Characteristics of RF-Only Devices:  Quadrupoles and Octupoles as Ion Pipes “  Compares the transmission characteristics of Quadrupoles and Octupoles in RF-Only mode.

RA_2006

General Quadrupole Theory

“ Improving Abudance Sensitivity in Quadrupole Mass Spectrometers “ Shows the effect of Ion Energy, RF Operating Frequency and RF-only Pre- and Post-filters on the ability to resolve adjacent peaks of widely different intensities.

RA_2007

High Mass

“  Optimizing Quadrupole Transmission for Wide Mass Range to 10,000 amu “  Proves a summery of practical hints for maximizing performance at high mass along with ion energy and tuning requirements

RA_2009

High Mass

Transmission Characteristics of Quadrupoles to m/z 10,000” Explorers the trade off in Sensitivity and Resolution versus Mass Range

RA_2010

General Quadrupole Theory

Practical Quadrupole Theory:  Graphical Theory “  This a simplified description of the operation of Quadrupole Mass Filters  without complicated equations.

RA_2201

General Quadrupole Theory

Quadrupole Mass Spectrometry Using the Second Mathieu Stability Region”  Discusses the effect on Abundance Sensitivity, Sensitivity and Resolution of operating in alterante stability regions. Shows the separation of Helium 3 and Deuterium which are 0.0256 amu apart.

RA_2202

General Quadrupole Theory

Measurement of m/z 1 and 2 on a 4000 amu System Using the Second Mathieu Stability Region “  Shows the performance of a high mass range system at low mass using alternate stability region operation

RA_2203

General Quadrupole Theory

Resolving Isobaric Masses Using a Quadrupole in the Second Mathieu Stability Region “  Shows the improvement of Abundance Sensitivity and Resolution using alternate stability regions.  Concentrates on the separation of CO and N2 at m/z 28 and CO2 and N2O at m/z 44.

RA_2400

General Quadrupole Theory

“  He/D2 Mass Sparation with the Faraday detector: a Comparision between the First and Second Mathieu Stability Region “Shows the performance of a high mass range system at low mass using alternate stability region operation

RA_5011

Material Science, Ion Chemistry

Measurement of Appearance Potentials “  Practical guide for measureing the Appearance Potentials of Gaseous Molecules.

RA_5201

Material Science, Ion Chemistry

Real Time Monitoring and Detection of Trace H2  and HF Species in an Argon Based Plasma “  High Abundance and High Resolution sampling of Isobaric Masses in a Plasma using a two stage molecular beam sampling system.

RA_5202

Material Science, Ion Chemistry

Analysis of Fast Neutral in Plasma Monitoring “  Improving the performance of Al and Cu Sputtering processes through the analysis of Fast Neutrals produced by the plasma.  

RA_5103

Material Science, Ion Chemistry

"Using the Tandem Ionizer/Energy Filter and the Merlin Automation Data System to analyze internal and external ions." Effecient use of a combination Axial Ionizer and Beam Stop Type Energy Filter to separate ions of  different kinetic energies.

SA_5102

Gas Analysis 

       “ Lower Detection Limits of Atmospheric Pressure Ionization  Mass Spectrometry “  Shows sub-ppt Detection Limits for an APIMS system and how they are derived.