Depending on customer preferences and application requirements, the Extrel CMS process analyzer can be equipped with a variety of inlets switched, multi-port inlets under software control. In many cases, combinations of inlet technology may be appropriate.
Fast Clearing, Low Volume Inlets - Rotary Valve Option
 |
Rotary valves take full advantage of the speed of the Extrel CMS Gas Analysis Systems and can be configured for positive pressure, ambient and sub-ambient pressure applications. More information |
High Volume, Environmental Inlet - The Extrel Fast Valve
 |
The Fast Valve is an 80-position valve designed to move large amounts of gas quickly to the analyzer. Environmental applications are particularly suited for the Fast Valve. More information |
Linear Solenoid Inlets
 |
Both pneumatic and electrically operated solenoid inlets are available in various configurations to provide a robust inlet for a variety of difficult sampling applications. More information |
Relay Outputs
The MAX300-IG and MAX300-LG Gas Analysis Systems can provide contact closures rated for 220 volts at 2 amps to control existing or customer-provided inlets.
DCS Control Option
The MAX300-IG and MAX300-LG Gas Analysis Systems can be controlled by an external DCS or control system via a digital command interface. Up to 128 different commands can be accepted including analysis, calibration, scans or tune functions.